Customization: | Available |
---|---|
Certification: | RoHS, ISO, CE |
Power Supply: | AC380V |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Item Description | |
Input signal | 4-20mA,0-10V(Optional)Four binary signals(OPEN,CLOSE,STOP,EMERGENCY) |
|
Output signal | 4-20mA(Load impedances≤750Ω) 5 relay dry contact signals(contact capacity 220V/1A) | |
Power supply | AC220V/380V±15%(Others can be customized) | |
Control mode |
DC4-20mA Analog control | |
Switching control(OPEN,CLOSE,STOP,EMERGENCY) | ||
PROFIBUS DP Modbus(optional) | ||
Basic Error | ≤0.5% | |
Return difference | ≤0.5% | |
Dead Band | 0.3-5% adjustable | |
Operating mode | S4-1200 times per hour:S2-15min,S2-30min | |
Protecting Function | Over torque,over voltage,over current,remote control of signal breaking | |
Additional Function | Torque,speed adjustable,flexible start and stop | |
Environment Condition | Environment Temperature | -25--+70ºC |
Environment Humidity | 5-95% | |
Mechanical Oscillation | With frequency rate within 10-200HZ,the acceleration rate can reach a lasting oscillation of 0.5g | |
Degree of protection | IP67(IP68 is customized) |
Type | Adjustable tripping torque | Maximum rotation |
Output speed |
Flange size |
2SA5510/2SA5010 | 9-30 | 0.8-4020 | 5-40/10-80/20-160 | F07 |
2SA5511/2SA5011 | 9-30 | 0.8-4020 | 5-40/10-80/20-160 | F10 |
2SA5521/2SA5021 | 18-60 | 0.8-4020 | 5-40/10-80/20-160 | F10 |
2SA5531/2SA5031 | 37-125 | 0.8-4020 | 5-40/10-80/20-160 | F10 |
2SA5532/2SA5032 | 37-125 | 0.8-4020 | 5-40/10-80/20-160 | F12 |
2SA5533/2SA5033 | 75-250 | 0.8-4020 | 5-40/10-80/20-160 | F14 |
2SA5542/2SA5042 | 75-250 | 0.8-4020 | 5-40/10-80/20-160 | F12 |
2SA5543/2SA5043 | 75-250 | 0.8-4020 | 5-40/10-80/20-160 | F12 |
2SA5553/2SA5053 | 150-500 | 0.8-4020 | 5-40/10-80/20-112 | F12 |
2SA5554/2SA5054 | 150-500 | 0.8-4020 | 5-40/10-80/20-112 | F16 |
2SA5564/2SA5064 | 300-1000 | 0.8-4020 | 5-40/10-80 | F16 |
2SA5575/2SA5075 | 600-2000 | 0.8-4020 | 2.5-20/5-28 | F25 |
2SA5586/2SA5086 | 1200-4000 | 0.8-4020 | 1.25-10/2.5-20 | F30 |
Type | Reduction ratio |
Output torque(Nm) |
Input torque(Nm) |
Input flange |
Output flange | Magnification | Weight | |
IS05210 | JB2920 | (KG) | ||||||
GST04 | 2.5:1 | 675 | 340 | F14 | 4 | 2 | 13 | |
GST05 | 6:1 | 1350 | 270 | F14 | 5 | 5 | 22 | |
GST07 | 3.8:1 | 3000 | 1000 | F16 | 7 | 3 | 60 | |
GST07 | 3:1 | 3000 | 1200 | F16 | 7 | 2.5 | 60 | |
GST08 | 3.5:1 | 6000 | 2100 | F16 | 8 | 2.8 | 60 |
Type | Reduction ratio |
Output torque(Nm) |
Input torque(Nm) |
Input flange |
Output flange | Magnification | Weight (KG) |
|
ISO5210 | JB2920 | |||||||
GK10.2 | 4:1 | 120 | 34 | F10 | 2 | 30.6 | 13 | |
GK14.2 | 4:1 | 250 | 70 | F10 | 3 | 3.6 | 14 | |
GK14.6 | 4:1 | 500 | 139 | F14 | 4 | 3.6 | 18 | |
GK16.2 | 4:1 | 1000 | 278 | F14 | 5 | 3.6 | 33 | |
GK16.2 | 6:1 | 1000 | 200 | F14 | 5 | 5 | 35 | |
GK25.2 | 4:1 | 2000 | 556 | F16 | 7 | 3.6 | 56 | |
GK25.2 | 6:1 | 2000 | 400 | F16 | 7 | 5 | 58 | |
GK30.2 | 4:1 | 4000 | 1112 | F25 | 8 | 3.6 | 85 | |
GK35.2 | 4:1 | 8000 | 2224 | F35 | 9 | 3.6 | 120 | |
GK40.2 | 4:1 | 16000 | 4448 | F40 | 10 | 3.6 | 330 |
Items | 2SA5…Series electric actuators | Domestic electric actuators |
Motor drive | Vector frequency drive control, speed and torque are adjustable, long service life | AC contactor or solid-state relay driven, lifespan of the drive is short, speed is fixed. |
Failure diagnosis |
Failure warning for phase failure, over current, over voltage, under voltage, motor overheating, the electronic unit overheating. Over torque and interrupt signal etc. It benefits the user figure out issues on time and protect the actuator |
Don' t have diagnosis function, causing inconvenience to maintenance |
energy saving and eco-friendly | Adopt vector frequency drive control, reducing energy consumption, using 30% less energy than similar products | AC contactor drive, consume energy heavily |
Control interface |
Adopt 4-20mA or PROFIBUS-Dp bus control, diversification of control methods | Adopt traditional 4-20mA control, single control method |
Valve protection |
speed can be controlled, flexible opening/closing function, have no impact on valve | Constant speed, have bad impact on valve and shorten the valve's life |
Control accuracy |
Adaptive control algorithm, speed is adjustable, high control precision | Speed is not adjustable, low positioning accuracy |
Spare part inventory | Frequency converting control and software function, reducing the spare part inventory | Traditional torque is not adjustable, must keep a lot of spare part inventory |
Q1.How about your price?
Although high quality but the price is vary favorable.
Q2. What is your MOQ?